Throughout any inspection campaign non-compliant issues are going to be found. Here are some common issues we have found whilst conducting inspections on  pressurised/ purged or ventilated equipment.

  • If an Ex p or Ex v house or container, no Statement of Assessment (report) exists to indicate compliance to an acceptable standard
  • Installed equipment, intended to operate until the environment is purged and/or pressurised, is not explosion protected
  • Ex p: The minimum internal overpressure cannot be achieved as per the design standard
  • Ex v: The minimum flow rate cannot be achieved as per the design standard Door or cover seals are perished or missing
  • Documentation missing or incorrect
  • Certificate of Conformity not read
  • Labels missing or illegible
  • Cable damage
  • The inlet and outlet ports are not positioned correctly
  • Inadequate protective pressure / flow
  • Dirty filters
  • Pressure outside the permitted range
  • Faulty instrumentation, gauges and meters
  • Build up of dust or dirt
  • Incorrect application or use of the equipment

What others can you think of?


This material is produced by HAZ. The information is of a general nature only and should not be relied upon.  Each set of circumstances associated with compliance of hazardous areas and Type B compliance is unique and expert advice on your particular circumstances should be sought.  HAZ accepts no liability for any reliance on the information published on this website.